Page #29 background imageLoading...
Page #29 background image
Studer Innotec SA
Quick guide RCC-02/-03
Quick guide V 6.1.0 29
Nr
Name
Unit
Xcom-CAN information description
7058
hSOC
%
High resolution State of Charge
7061
UChL
Vdc
Charge voltage limit
7062
UDiL
Vdc
Discharge voltage limit
7063
IChL
Adc
Charge current limit
7064
IDiL
Adc
Discharge current limit
7065
IChR
Adc
Recommended charge current
7066
IDiR
Adc
Recommended discharge current
7.4 USER INFORMATION ON VARIOTRACK DISPLAYS
Nr
Name
Unit
VarioTrack information description
11000
Ubat
Vdc
Battery voltage
11001
Ibat
Adc
Battery current
11002
Upv
Vdc
Voltage of the PV generator*
11004
Psol
kW
Power of the PV generator
11005
Tbat
°C
Battery temperature
11006
Cd
Ah
Production in (Ah) for the current day
11007
Ed
kWh
Production in (kWh) for the current day
11008
kWhR
kWh
Produced energy resettable counter
11009
MWhT
MWh
Total produced energy
11010
Cd-1
Ah
Production in (Ah) for the previous day
11011
Ed-1
kWh
Production in (Wh) for the previous day
11015
Type
Text
Model of VarioTrack (VT-80, VT-65)
11016
Mode
Text
Operating mode (Night, StartUp, ---, Charger, ---, Security, OFF, -
--, Charge, Charge V, Charge I, Charge T, Ch. Ibsp)
11017
PVmx
Vdc
Max PV voltage for the current day*
11018
Ibmx
Adc
Max battery current of the current day
11019
PVxP
kW
Max power production for the current day
11020
Bmax
Vdc
Max battery voltage for the current day
11021
Bmin
Vdc
Min battery voltage for the current day
11025
Sd
h
Number of irradiation hours for the current day
11026
Sd-1
h
Number of irradiation hours for the previous day
11034
Err
Text
Type of error (No Error, BatOverV, Earth, No Batt, OverTemp,
BatOverV, PvOverV, Others, ---, ---, ---, ---, HardErr)
11037
EqIn
days
Number of days before next equalization
11038
Phas
Text
Battery cycle phase (Bulk, Absorpt., Equalize, Floating, ---, ---,
R.float., Per.abs., ---, ---, ---, ---)
11066
Sync
Text
Synchronisation state (---, ---, ---, ---, XTslave, VTslave, ---, ---,
VTmaster, Autonom., VSslave, VSmaster)
11069
VT state
Text
State of the VarioTrack (Off, On)
11076
locEr
Local daily communication error counter (CAN)
11082
RME
Text
Remote entry state (RM EN 0, RM EN 1)
*This information is not visible on the shared display (Multi) over all VT devices. It will however show on the
individual display on each device.

Other manuals for Studer RCC-02

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Studer RCC-02 and is the answer not in the manual?

Studer RCC-02 Specifications

General IconGeneral
BrandStuder
ModelRCC-02
CategoryRemote Control
LanguageEnglish