Explains symbols, terminology, and warnings used in the manual.
Provides information on product disposal and environmental compliance.
Details the warranty terms, coverage, and exclusions for the product.
Outlines the limitations of liability for the manufacturer.
Crucial precautions for safe operation and handling of the device.
Terms and conditions for using the software and its updates.
Lists the Xtender models compatible with this remote control.
Describes the function of buttons and the display on the remote control.
Explains how to connect multiple devices in a series network.
Provides the physical dimensions for the RCC-02 unit.
Provides the physical dimensions for the RCC-03 unit.
Step-by-step guide to setting the display language.
Configures the unit to match the connected power source characteristics.
Sets all Xtender parameters to their defined threshold values.
Restores the default threshold values for Xtender parameters.
Enables or disables the automatic data logging function.
Forces a backup of the data recorded for the current day.
Performs a complete backup of system files including configurations.
Restores the system configuration from a saved backup file.
Saves message history files (event history) to the SD card.
Commands for saving and restoring files specific to the RCC remote control.
Commands for saving and restoring files specific to Xtender inverter-chargers.
Sets the backlight behavior: always on, off, or delayed.
Determines how long the backlight stays active after inactivity.
Configures red backlight to indicate an OFF state or fault.
Selects the default screen displayed upon menu exit or connection.
Sets the time before the display reverts to the basic screen.
Sets the display duration for less critical messages.
Enables or disables audible alarms for system events.
Adjusts the duration of the acoustic alarm sound.
Restricts ON/OFF control when the unit is in 'View Only' mode.
Indicates a low battery voltage warning and its potential consequences.
Shows the status of the AC input synchronization process.
Details how the data logger function operates and records system data.
Explains how to use the analysis tool for CSV data interpretation.
Overview of basic Xtender configuration principles.
Guidelines for configuring systems with multiple Xtender units.
Describes user levels and their respective access permissions.
Information on factory pre-set functions for auxiliary relays.
Method for accessing and modifying parameters using their reference number.
Method for navigating and accessing parameters through the menu structure.
Configures basic parameters using the XTS potentiometer controls.
Sets the battery undervoltage level for deactivating inverter/Smart Boost.
Enables dynamic adjustment of battery undervoltage disconnection voltage.
Selects the type of dynamic compensation for battery undervoltage.
Allows forcing the start of a new battery charge cycle.
Sets voltage and duration for the first new cycle condition.
Sets voltage and duration for the second new cycle condition.
Enables or disables the battery absorption charging phase.
Sets the voltage level used during the absorption phase.
Sets the duration for the battery absorption charging phase.
Enables or disables the battery equalization charging phase.
Allows forcing the start of a battery equalization phase.
Enables the reduced floating phase for lower water consumption.
Sets the duration of the floating phase before reduced floating.
Sets the voltage level for the reduced floating phase.
Authorizes the operation of the inverter function.
Allows adjustment of the inverter's output voltage.
Sets the power level at which the inverter enters standby mode.
Determines the interval between standby pulses for load detection.
Sets the number of periods generated during a standby burst.
Authorizes or prohibits the operation of the transfer relay.
Sets a delay before the transfer relay closes, even if AC-In voltage is present.
Authorizes the Smart-Boost function to supplement power from batteries.
Limits the maximum power provided by the Smart-Boost function.
Allows using a secondary value for AC source current limit.
Sets a second maximum current value used when command entry is active.
Decreases max source current based on input voltage when command entry is active.
Configures generator startup sequence using auxiliary contacts.
Manages the generator start impulses and sequence.
Sets the maximum number of generator start attempts.
Adjusts the timing of the starter pulse activation.
Sets the time delay before a starter pulse or restart.
Sets the hold/interrupt time for the main contact during cranking.
Customizes various settings related to the command entry input.
Sets limits for battery undervoltage restarts before permanent deactivation.
Sets limits for critical battery undervoltage restarts before permanent deactivation.
Sets the delay before the unit attempts to restart after an overload.
Prohibits the connection between neutral and ground.
Ensures the AC-out neutral remains connected to the AC-in neutral.
Authorizes or prohibits the grid-feeding function.
Sets the limit for the grid-feeding current.
Information on hardware and software versions of remote controls.
Information on connected Xtender units and their versions.
Step-by-step guide for updating the system software.
Illustrates a standard setup with grid connection and basic functions.
Example of using limited power sources like generators or dock connections.
A table detailing dependencies between various configuration parameters.
Reference table listing parameters for the RCC remote control.