Studer Innotec SA
RCC-02/-03
68 V4.4.0 User manual
14.13 SYSTEM {1101}
14.13.1 Command entry {1537}
The following parameters allow to customize the command entry.
14.13.1.1 Command entry active {1545}
This parameter allows you to determine if the command entry is activated closed or open.
14.13.1.2 Prohibits transfer relay {1538}
If this parameter is activated, the command entry forbids the closing of the transfer relay.
14.13.1.3 Inverter prohibited {1539}
If this parameter is activated, the command entry forbids the inverter function.
14.13.1.4 Charger prohibited {1540}
If this parameter is activated, the command entry forbids the battery charger function.
14.13.1.5 Smart Boost prohibited {1541}
If this parameter is activated, the command entry forbids the Smart-Boost function.
14.13.1.6 Forbids grid-feeding {1542}
This parameter forbids the grid-feeding by means of the command entry.
14.13.1.7 Use a secondary max input current {1566}
If this parameter is activated, the value set for the max current of the source is reversed with the value
programmed by the parameter below.
14.13.1.8 Alternate max. input current {1567}
Value used instead of the main value when the control entry is activated.
Use this function if you connect regularly two different sources like a genset and shore
power. By using this function, you can go from one input limit to another without
having to program the maximum value at each change of source.
14.13.1.9 Decrease of the source max. current with the input voltage {1527}
This parameter forces the adaptation of the max. current of the source to the AC-In voltage. In case
of sources with limited power (like a generator) the presence of big consumers at the output can
generate a voltage drop. The setting of this parameter will help diminishing the current taken from
the source in order to stabilize somehow the voltage.
When the Smart-boost function is activated both the battery charge current and the
Xtender power assistance are adapted.
14.13.1.10 Command ON/OFF {1576}
When this parameter is active, a pulse on the function input enables to put the Xtender ON or OFF.
Max. duration of the pulse is 200ms.