6.5 CONFIGURATION OF THE VARIOTRACK (MPPT SOLAR CHARGE CONTROLLER)
Level
Nr
VarioTrack parameter description
Factory value
Basic
10000
BASIC SETTINGS
Expert
10054
Block manual programming (dip-switch)
No
Basic
10001
Voltage of the system
Automatic
Basic
10037
Synchronisation battery cycle with Xtender
Yes
Basic
10005
Floating voltage
13.6/27.2/54.4 Vdc
Basic
10009
Absorption voltage
14.4/28.8/57.6 Vdc
Basic
10017
Equalization allowed
No
Basic
10021
Equalization voltage
15.6/31.2/62.4 Vdc
Basic
10056
Restore default settings
-
Inst.
10057
Restore factory settings
-
Expert
10003
BATTERY MANAGEMENT AND CYCLE
Basic
10037
Synchronisation battery cycle with Xtender
Yes
Expert
10002
Battery charge current
80 Adc
Expert
10334
Battery undervoltage
10/20/40 Vdc
Expert
10036
Temperature compensation
-3 mV/°C/cell
Expert
10004
Floating phase
Basic
10005
Floating voltage
13.6/27.2/54.4 Vdc
Expert
10006
Force phase of floating
-
Expert
10007
Absorption phase
Expert
10008
Absorption phase allowed
Yes
Basic
10009
Absorption voltage
14.4/28.8/57.6 Vdc
Expert
10010
Force absorption phase
-
Expert
10011
Absorption duration
120 min
Expert
10012
End of absorption triggered by the current
No
Expert
10013
Current threshold to end absorption phase
10 Adc
Expert
10016
Equalization phase
Basic
10017
Equalization allowed
No
Expert
10018
Force equalization
-
Basic
10021
Equalization voltage
15.6/31.2/62.4 Vdc
Expert
10020
Equalization current
80 Adc
Expert
10022
Equalization duration
30 min
Expert
10052
Equalization with fixed interval
Yes
Expert
10025
Days between equalizations
26 days
Expert
10026
End of equalization triggered by the current
No
Expert
10027
Current threshold to end equalization phase
10 Adc
Expert
10019
Equalization before absorption phase
Yes
Expert
10028
New cycle
Expert
10029
Force a new cycle
-
Expert
10030
Voltage level 1 to start a new cycle
12.2/24.4/48.8 Vdc
Expert
10031
Time period under voltage level 1 to start a new cycle
30 min
Expert
10032
Voltage level 2 to start a new cycle
11.8/23.6/47.2 Vdc