Section 2
DESCRIPTION
12
(82_C) with ambient and water temperatures less
than 80_F(27_C).
S The air filter restriction gauge monitors the con-
dition of the air intake filter. When pointer reaches
the red zone, filter service is required (see Figure
2 --- 2 ) .
S The START pushbutton turns the compressor on
and resets t he compressor.
S The STOP pushbutton turns the compressor off.
S The hourmeter records cumulative hours of op-
eration of the compressor. It is useful for planning
and logging service operations.
S The separator maintenance gauge monitors the
condition of the separator element(s). Pointer will
move into the red zone when the element(s) should
be replaced. This gauge is automatically reset after
the element has been replaced.
S The fluid filter maintenance gauge monitors the
condition of the bearing fluid filter element. P ointer
will move into the red zone when the element should
be replaced. This gauge is also automatically reset
after elements have been changed.
S The red light on the instrument panel indicates
when power to the compressor is supplied.
S The green light indicates w hen the compressor is
running.