Section 3
SPECIFICATIONS
14
LUBRICATION GUIDE-- STANDARD COMPRES-
SORS
Sullair 32 Series standard compressors are filled
with Sullube 32 fluid as factory fill. (MIXING OF
OTHER FLUIDS WITHIN THE COMPRESSOR
SHOULD BE AUTHORIZED BY THE FACTORY
OTHERWISE THIS WILL VOID ALL WARRAN-
TIES).
Sullube 32 fluid should be changed every 8000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particulate level, corrosive gases or strong oxi-
dizing gases a re present in the air.
Sullair encourages the user to participate in a fluid
analysis program with the fluid suppliers. This could
result in an fluid change interval differing from that
stated in the manual. Contact your Sullair dealer for
details.
Maintenance of all other components is s till recom -
mended as indicated in the Operator’s Manual.
LUBRICATION GUIDE-- 24KT COMPRESSORS
Sullair 24KT compressors are filled with a lubricant
which rarely ever needs to be changed. In the event
a change of fluid is required, use only Sullair 24KT
fluid. MIXING OF OTHER FLUIDS WITHIN THE
COMPRESSOR WILL VOID ALL WARRANTIES.
Sullair recommends that a 24KT s ample be taken at
the first filter change and sent to the factory for
analysis. This is a free service. A sample kit with in-
structions and self---addressed container is to be
supplied by your Sullair representative at start---up.
The user will receive an analysis report with recom -
mendations.