Section 5
OPERATION- ELECTRO-MECHANICAL
25
5.1 GENERAL
While Sullair has built into this compressor a com-
prehensive array of controls and indicators to as-
sureyouthat itisoperating properly, youwill want to
recognizeandinterpret thereadingwhichwillcallfor
service or indicate the beginning of a malfunction.
Before starting your Sullair compressor, read this
section thoroughly and familiarize yourself with the
controls and indicators -- their purpose, locationand
use.
5.2 PURPOSE OF CONTROLS--STANDARD ELECTRO-MECHANICAL
CONTROL OR INDICATOR PURPOSE
EMERGENCY STOP SWITCH Pushing inthis switch, found adjacentto thecontroller,
cuts all AC outputs from the latter and de--energizes
the starter. A fault message (E STOP) is displayed by
theSupervisor untilthebutton is pulled outand the O
pad is depressed.
START I PAD Depress to turn the compressor ON.
STOP O PAD Depress to turn the compressor OFF and reset the com-
mon fault circuit.
AUTO
PAD To select between continuos (HAND) operation and au-
tomatic stop/start (AUTO)operation. Shuts offcompres-
sorautomatically after the compressor runs unloadedfor
a specified time (ranging from 3--60 minutes [T1]). Re-
starts compressor when the pressure switch trips to the
reload setting. Dual control is enabled by pressing the
“AUTO” pad.
HOURMETER Records cumulative hours of compressor operation;
useful for planning and logging service schedules.
LINE PRESSURE GAUGE Continually monitors service line air pressure. It is lo-
cated on dry side of receiver downstream from check
valve.
SUMP PRESSURE GAUGE Continually monitors receiver/sump pressure at vari-
ous load and/or unloaded conditions.
DISCHARGE TEMPERATURE GAUGE Monitors temperature ofthe airleaving the compressor
unit. For both air and water--cooled compressors, the
normal reading should be approximately 180_Fto
205_F(82_Cto96_C).
AIR FILTER RESTRICTION GAUGE Indicates whentheairfilter element changeisrequired.
The gauge shows the red zone when drop through the
filter is excessive. Thecompressor must berunningfull
load for an accurate indication.
FLUID FILTER MAINTENANCE GAUGE Indicates whena fluid filter elementchange isrequired.
It shows redwhenthe pressure dropthroughthefilteris
excessive.
SEPARATOR MAINTENANCE GAUGE Indicates when separator element change is required.
Shows red when the pressure drop through the filter is
excessive. The compressor must be running full load
for an accurate indication.
POWER ON (
) LED Indicates when the starter is receiving power.
ON LED Indicates when compressor is in operation.
AUTO LED Indicates when compressor is in auto mode.