Section 1
SAFETY
2
1.4 FIRE AND EXPLOSION
WARNING
!
When installing a Base Load Transfer (BLT) Sys-
tem, remove jumpers between 16--17 & 18--19
(Dual Control Compressors) so the other com-
pressor does not backfeed defeating the shut-
down circuitry.
A. Clean up spills of lubricant or other combustible
substances immediately, if such spills occur.
B.Shutoffthecompressorandallowittocool. Then
keep sparks, flames and other sources of ignition
away and
DO NOT
permit smoking in the vicinity
when checking or adding lubricant or when refilling
airlineanti--icer systems with antifreezecompound.
C. DO NOT permit fluids, including air line anti--icer
system antifreeze compound or fluid film to accu-
mulate on, under, or around acoustical material, or
onanyexternal surfaces of the aircompressor oron
internalsurfaces of the enclosure. Wipe downusing
anaqueousindustrial cleaner or steam--clean asre-
quired. If necessary, remove acoustical material,
cleanallsurfaces and thenreplaceacousticalmate-
rial. Any acoustical material with a protective cover-
ing that has been torn or punctured should be re-
placed immediately to prevent accumulation of liq-
uids or fluid film within the material.DONOTuse
flammable solvents for cleaning purposes.
D. Disconnect andlock out all powerat source prior
to attempting any repairs or cleaning of the com-
pressor or of the inside of the enclosure, if any.
E. Keep electrical wiring, including all terminals and
pressureconnectorsingoodcondition. Replaceany
wiring that has cracked, cut abraded or otherwise
degraded insulation, or terminals that are worn, dis-
colored or corroded. Keep all terminals and pres-
sure connectors clean and tight.
F. Keep grounded and/or conductive objects such
as tools away from exposed live electrical parts
such as terminals to avoid arcing which might serve
as a source of ignition.
G.
Removeanyacousticalmaterialor othermaterial
that may be damaged by heat or that may support
combustion and is in close proximity, prior to at-
tempting weld repairs.
H. Keep suitable fully charged fire extinguisher or
extinguishers nearby when servicing and operating
the compressor.
I.
Keep oily rags, trash, leaves, litter or other com-
bustibles out of and away from the compressor.
J. DO NOT
operate the compressor without proper
flowof coolingairorwater or with inadequate flow of
lubricant or with degraded lubricant.
K. DO NOT attempt to operate the compressor in
any classification of hazardous environment unless
the compressor has been specially designed and
manufactured for that duty.
1.5 MOVING PARTS
A. Keep hands, arms and other parts of the body
andalsoclothingawayfromcouplings,fansandoth-
er moving parts.
B. DO NOT attempt to operate the compressor with
the fan, coupling or other guards removed.
C. W ear snug--fitting clothing and confine long hair
when working around this compressor, especially
when exposed to hot or moving parts.
D. Keep access doors, if any, closed except when
making repairs or adjustments.
E. Make sure all personnel are out of and/or clearof
the compressor prior to attempting to start or oper-
ate it.
F. Disconnect and lock out all power at source and
verify at the compressor that all circuits are de--en-
ergized to minimize the possibility of accidental
start--up or operation, prior to attempting repairs or
adjustments. This is especially important when
compressors are remotely controlled.
G. Keep hands, feet, floors, controls and walking
surfaces clean and free of fluid, water, or other liq-
uids to minimize the possibility of slips and falls.
1.6 HOT SURFACES, SHARP EDGES AND SHARP
CORNERS
A. Avoid bodily contact with hot fluid, hot coolant,
hot surfaces and sharp edges and corners.
B.
Keep all parts of the body away from all points of
air discharge.
C.
W ear personal protective equipment including
gloves and head covering when working in, on or
around the compressor.
D. Keep a first aid kit handy. Seek medical assis-
tance promptly in case of injury. DO NOT ignore
small cuts and burns as they may lead to infection.
1.7 TOXIC AND IRRITATING SUBSTANCES
A.DONOTuseairfrom thiscompressor forrespira-
tion (breathing) except in full compliance with any
Federal, State or Local Codes or regulations.
DANGER
!
Death or serious injury can result from inhaling
compressed air without using proper safety
equipment.
B. DO NOT useairlineanti--icersystemsinairlines
supplying respirators or other breathing air utiliza-
tion equipment and
DO NOT
discharge air from
these systems in unventilated or other confined
areas.