Section 3
SPECIFICATIONS
27
3.1 SPECIFICATIONS- LS16T
DIMENSIONS WITHOUT ENCLOSURE (I)
Model Series Length Width Height Weight
in mm in mm in mm lb kg
LS16T 250 CFM 108.0 2744 71.69 1821 71.5 1816 6200 2812
LS16T 360 CFM 108.0 2744 71.69 1821 71.5 1816 6500 2949
LS16T 425 CFM 108.0 2744 71.69 1821 71.5 1816 6850 3108
(I) For information concerning enclosed compressors, please contact the Sullair Factory Sales Department.
For noise level information, please contact the Sullair Factory Service Department.
3.2 LUBRICATION GUIDE-STANDARD COMPRES-
SORS
Refer to Figure 3-1 for fluid fill port location. Sullair
standard compressors are filled with Sullube fluid
as factory fill.
To be sure that you receive the correct fluid for
your compressor, when ordering fluid, always
confirm your compressor’s fluid fill with the parts
technician by using your compressor’s serial
number.
Mixing of other fluids within the compressor will
void all warranties.
Sullube fluid should be changed every 1800 hours
or once a year, whichever comes first. The fluid
should be changed more frequently under severe
operating conditions, such as high ambient temper-
atures coupled with high humidity, or when high
particulate level, corrosive gases or strong oxidizing
gases are present in the air.
Maintenance of all other components is still recom-
mended as indicated in the Operator’s Manual.
COMPRESSOR:
Type: 2-Stage Oil Flooded Rotary
Maximum Full Load Operating Pressure: 350 psig (24.1 bar)
Bearing Type: Anti-Friction
Cooling: Pressurized Compressor Fluid
Lubricant: Sullube
System Fluid Capacity (refill): 30 U.S. Gallons (113.6 Liters)
Control: Supervisor II Controller
MOTOR:
Type: O.D.P., 460V, A.C., Three Phase, 60 Cycles
Size: 100, 125, 150 and 200HP
Speed: 1800 RPM
Figure 3-1 Fluid Fill Port Location