SD-220 / SD-600
DDS OPTION
3V OPTION
SD Heatless Desiccant
Compressed Air Dryers
REF: 02250130-734
SERIES SD

Table of Contents

Questions and Answers

  • L
    Leslie LeeAug 17, 2025
    What to do if the dryer does not switch towers in Sullair SD-220 Dehumidifier?
    • W
      Wendy BaileyAug 17, 2025
      If your Sullair Dehumidifier's dryer isn't switching towers, several factors could be at play. The inlet valve combination might not be opening or switching; in this case, check the electrical functioning of the solenoids and replace either the solenoid or the complete valve combination. Another reason could be that the PLC isn't functioning; check the PLC and the fuse in the control cabinet. The vessel might not be pressurized; check whether the blow-off valves are dirty and replace them if necessary, and check the electrical functioning of the solenoids, replacing either the solenoid or the complete valve combination. The regeneration orifice might be obstructed; clean or replace it.
  • J
    Jessica RichardsonAug 25, 2025
    How to fix high back pressure during regeneration phase in Sullair Dehumidifier?
    • J
      Jacqueline JacksonAug 25, 2025
      High back pressure during the regeneration phase in your Sullair Dehumidifier can stem from a few issues. The silencer might be blocked; clean or replace it. The inlet/exhaust valve cylinders could be defective; lubricate the cylinder, replace seals if necessary, or replace the cylinder. Also, the check valves might not be sealing; repair the check valve.
  • P
    Pamela GarciaNov 8, 2025
    Why is the dew point too high in my Sullair SD-220 Dehumidifier?
    • A
      amy92Nov 8, 2025
      If the dew point is too high in your Sullair Dehumidifier, it could be due to several reasons. The operating pressure might be too low, or the air flow capacity might be too high; in this case, increase the operating pressure and reduce the air flow capacity. Another cause could be that the air inlet temperature is too high; reduce the temperature, or connect an air cooler upstream. Also, the differential pressure at the pre-filter might be too high; check the filter element for impurities and change it if necessary. The condensate drain might not be functioning; check its operation and replace it if needed. The desiccant could be soiled or have disintegrated; check the pre-filter for impurities, change the filter element, and replace the desiccant, disposing of the old desiccant. The volu...
  • M
    Matthew RhodesDec 3, 2025
    What to do if my Sullair Adsorption Dryer does not switch over?

    Summary

    SECTION 1 INTRODUCTION

    1.2 SAFETY INSTRUCTIONS

    Essential safety guidelines for operation, maintenance, and handling.

    1.3 PERSONNEL QUALIFICATION

    Outlines the necessary qualifications and training for personnel.

    SECTION 2 INSTALLATION

    2.1 SET-UP AND INSTALLATION

    Guides on positioning, piping, and electrical connections for installation.

    SECTION 3 START UP AND OPERATION

    3.1 START UP; SHUT DOWN

    Details the procedures for starting up and shutting down the dryer.

    3.2 DESCRIPTION OF THE OPERATION

    Explains the working principle and cycle of the adsorption dryer.

    3.2.1 Description of the operation

    Describes the 10-minute drying cycle and air flow.

    3.2.2 Dryer operating sequence (No control or alarm option)

    Outlines the step-by-step operation sequence for standard models.

    3.2.3 Operating sequence (DDS Option)

    Details the operating sequence for models with DDS option.

    3.2.4 Alarms

    Lists and explains the different types of alarms.

    3.2.5 Electrical control

    Covers electrical connections and control systems.

    3.3.1 DDS Controls

    Explains the dewpoint demand switching system and its features.

    3.3.2 DDS Controls - Start up and operation

    Guides on starting up and operating the DDS control system.

    SECTION 4 MAINTENANCE

    4.1 REPLACEMENT OF THE DESICCANT

    Provides step-by-step instructions for desiccant replacement.

    4.5 FILTERS

    Information on filter types, function, installation, and maintenance.

    SECTION 5 DRYER FLOW CAPACITY AND PURGE ADJUSTMENT

    SECTION 7 TROUBLE SHOOTING & FAULTS

    7.1 THE DEW POINT IS TOO HIGH

    Lists possible causes and solutions for high dew point issues.

    7.2 THE ADSORPTION DRYER DOES NOT SWITCH OVER

    Addresses issues where the dryer fails to switch between chambers.

    7.3 BACK PRESSURE IS TOO HIGH DURING REGENERATION PHASE

    Provides solutions for excessive back pressure during regeneration.

    7.5 SHUT-DOWN IN CASE OF A FAULT OR FOR MAINTENANCE

    Explains how to safely shut down the dryer for faults or maintenance.

    7.6 RE-STARTING

    Guides on the correct procedure for re-starting the dryer.

    Sullair SD-220 Specifications

    General IconGeneral
    BrandSullair
    ModelSD-220
    CategoryDehumidifier
    LanguageEnglish