INSTALLATION, START-UP & MAINTENANCE MANUAL
MODEL NO.: SD-220 TO SD-600- DDS OPTION
REV 0 – May 24,,.2001
22
SECTION 4
4.3 CHANGING OF THE REGENERATION ORIFICE
Depressurize and remove power from the dryer.
The regeneration orifice (Quantity = 2) are integrated into compression fittings
that are threaded directly into the top distribution block/check valve.
Unscrew the tubing compression nuts on the orifice fittings, as well as the
common tubing.
Remove regeneration orifice and re-install new orifice as required.
Verify all tubing compression nuts are properly secured.
NOTE: Consult