Section 4
ShopTek™ ST4, ST5, ST7, ST11, ST15 Three-phase 60 Hz User Manual 4: Installation
88292018-236 R00
Subject to EAR, ECCN EAR99 and related export control restrictions. 33
Installation
4.1 Compressor mounting—support 
and location
The compressor must have a stable firm foundation, or 
mounting structure that is rigid enough to keep the com-
pressor frame level, and maintain the alignment of the 
com
pressor and motor. Tie-down bolts of sufficient size 
must be used to ensure that the compressor frame is 
firmly anchored to its foundation. Rubber, cork, or other 
pliable materials can be inserted between the foundation 
and compressor frame to provide a uniform contact sur-
face.
• Use flex connectors to prevent piping loads 
fro
m being transmitted to the compressor.
• National and local electrical codes specifying 
the required clearances for the area around the 
electrical panel must be complied with.
• Ensure the lighting at the compressor’s location 
is sufficient for safe operation and mainte-
nance.
• The compressor’s location should be one that 
allows access for maintenance vehicles and lift-
ing equipment.
• The clearances around the compressor should 
permit easy access to all compressor compo-
nents.
• Walls and ceilings with soft or porous surfaces 
absorb sound and reduce ambient noise levels. 
Hard surfaces reflect noise and have little effect 
on ambient noise levels.
4.1.1 Outdoor installation (sheltered)
ShopTek packages are equipped with TEFC motors and 
have water tight controls that are IP54 rated and are suit-
able for sheltered outdoor installation.
The compressor should be mounted on a concrete pad. If 
the 
pad is not level, the compressor must be mounted in 
such a manner that its base or skid is level in relation to 
the pad’s surface and fully supported.
If the compressor will be exposed to blow
ing rain or 
snow, it should be housed in a covered, four-walled 
enclosure.
• Sheltered air-cooled machines must have their 
exha
ust air vented outside of the enclosure.
• Installations consisting of more than one com-
pressor should be done in such a manner that 
each compressor’s exhaust is directed away 
from the air intakes of other compressors or air 
dryers.
• A standard compressor should not be started if 
the ambient temperature is 35°F (1.7°C) or 
lower.
Compressor must not be operated in sub-freezing 
co
nditions.
 NOTE
Do not install compressors where the machine 
will be exposed to temperatures lower than 32°F 
(0°C). Contact Sullair Customer Care regarding 
operation in sub-freezing temperatures.