4: Installation ShopTek™ ST4, ST5, ST7, ST11, ST15 Three-phase 60 Hz User Manual
88292018-236 R00
38 Subject to EAR, ECCN EAR99 and related export control restrictions.
4.7 Motor rotation direction check
Motor rotation check must be done at compressor start-
up after the wiring has been installed. See Figure 4-4 and 
Figure 4-5. The compressor can be damaged if it runs in 
the wrong direction for more than a few seconds. Motor 
r
otation can be viewed through the openings in the belt 
guard. Pull out the EMERGENCY STOP button and 
press once, quickly and in succession, the   (START) 
pad and   (STOP) pad. This action will bump start the 
motor. When looking at the motor from the compressor 
un
it, the shaft should turn clockwise for ST4, ST5 and 
ST7 and counterclockwise for ST11 and ST15. If reverse 
rotation occurs, disconnect the power to the starter and 
exchange any two of the three power input leads, then 
re-check rotation. A “Direction of Rotation” decal is 
located on the motor drive housing to show proper motor/
compressor rotation.
Fan motor rotation should also be checked. It should 
r
otate counter-clockwise when viewing the fan motor 
from the backside of the motor.
Figure 4-4: Main motor/fan motor direction of
rotation—ST4, ST5, ST7
1. Main motor direction of rotation
2. Fan motor direction of rotation
Figure 4-5: Main motor/fan motor direction of
rotation—ST11, ST15
1. Main motor direction of rotation
2. Fan motor direction of rotation