10
Section 2
SUPERVISOR DESCRIPTION
Table 2-1 Supervisor Controller Menu Tree
T1 -Discharge
T2 -Dry Side*
T3- Oil*
T4 Interstage*
P1-Sump
P2-Line
P3-Oil Filter*
P4-Oil*
dP1-Separator
dP2-Oil Filt*
dP3-Oil*
Load Hours
Run Hours
Load Cycles
Starts
E-Stop String
Aux E-Stop
D1-Motor Ovld
D2-Aux Ovld
D3-Air Filter*
D4-Water Press*
D5-Remote Start
D6-Remote Unload
D7-Master Control
D8-Brownout
D9-Not Defined
D10-Not Defined
K1-Run
K2-Wye-Delta
K3-Load
K4-Full Load
K5-Drain
K6-Common Fault
K7-Common Warn
K8-Option
Unload Psi
Load Psi
Setpoint*
Unload Time
Drain Interval
Drain Time
Restart Time
Wye-Delta Time
Modulate Y/N
Language
Temp Units F/C
Press Units Psi/bar/kPa
Cost/KWH*
Saving VS*
Reset Load Est*
Info to be loaded by
Distributor for all con-
sumables
Last 16 faults
recorded
Capacity*
Capacity %*
Power*
Power %*
Recent Usage-------*
Hours*
Capactiy*
Capacity %*
Power*
Power %*
KCF*
KWH*
Cost*
Savings*
Lifetime Usages-----*
Hours*
Capacity*
Capacity %*
Power*
Power %*
KCF*
KWH*
Cost*
Savings*
Drive Status---------*
P2*
Motor RPM*
Frequency*
Drive Temp*
Motor Prot*
Status
VSD Status*
Control
Parameters
Maintenance
Sensor Log
Sequencing
System
Display
Calibration
Test
Factory
Setup
VSD
Setup*
MAIN SCREEN
Machine Status
Trouble State
P2-Line xxxPsi
T1-Discharge xxxF
Fault Log
T1 T2 P1 P2
T3 T4 P3 P4
Sequence By xxxxx
Sequence Hrs xxxxx
Com Number xx
Machines xx
Low Press xxx
Recover Time sec
Rotate (hours)
Minute xx
Hour xx
Day xx
Month xx
Year xxxx
Machine status
of Sequenced
machines
Password
P1
P2
dP
P3
P4
Cap
KW
Protect N/Y
Fault on Warn Y/N
Force Unload Y/N
Serial
communications
diagnostic
screen
Password
Set Defaults
Model
Cooling
Press Trans
P1 Max
KT Fluid
Water Switch
Oil Switch
Aux Overl0ad
Min Load Psi
Stop Timer
Lube Cycle
K8 Option
Load Hours
Run Hours
Load Cycles
Starts Capactiy
Sprial Valve*
VSD N/Y
Com Module N/Y
VSD Auto Set*
Nominal HP*
Nominal Volts*
VSD Max Amps*
Motor FLA*
Motor SF*
Motor V*
Motor Hz*
Motor RPM*
*
These parameters do not apply to some models.

Other manuals for Sullair SUPERVISOR CONTROLLER Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sullair SUPERVISOR CONTROLLER Series and is the answer not in the manual?

Sullair SUPERVISOR CONTROLLER Series Specifications

General IconGeneral
BrandSullair
ModelSUPERVISOR CONTROLLER Series
CategoryController
LanguageEnglish

Related product manuals