Section 3
SPECIFICATIONS
16
MOTOR: (60 Hz Compressors) STANDARD MODELS
Size: 100 - 250 HP/75 - 187KW
Type: Open Dripproof, 460V, A.C., Three Phase,
60 Cycles
105ºF (41ºC) Maximum Ambient Temperature,
TEFC also Available
Starter: 460V Full Voltage Magnetic
Options Available: 200 to 230 and 575V
3.2 LUBRICATION GUIDE-STANDARD COMPRES-
SORS
Sullair TS-20 compressors are filled with Sullube.
Sullube fluid should be changed every 8000 hours
or once a year, whichever occurs first. The fluid
should be changed more frequently under severe
operating conditions, such as high ambient temper-
atures coupled with high humidity, high particulate
level, corrosive or strong oxidizing gases are pres-
ent in the air.
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.
3.3 APPLICATION GUIDE
Sullair encourages the user to participate in a fluid
analysis program with the fluid suppliers. This could
result in a fluid change interval differing from that
stated in the manual.
For more information on a fluid analysis program,
contact your local Sullair representative or the
Sullair Factory Service Department.
Mixing of other fluids within the compressor will
void all warranties.
"The Plastic Pipe Institute recommends against
the use of thermoplastic pipe to transport com-
pressed air or other compressed gases in
exposed above ground locations, e.g. in
exposed plant piping." (I)
PVC piping should not be used with Sullube sys-
tems. It may affect the bond at cemented joints.
Certain other plastic materials may also be
affected.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.