EasyManua.ls Logo

Sulzer XJ Series - User Manual

Sulzer XJ Series
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Submersible Drainage Pump XJ (AT)
Submersible Drainage Center-line Pump XJC (AT)
Submersible Sludge Pump XJS (AT)
00833331AF 01.2016
www.sulzer.com
EN Starting and operating instructions 3
SV Start- och driftinstruktion 4
DE Inbetriebnahme- und Betriebsanleitung 5
FR Mise en service et utilisation 6
IT Instruzioni per l'avviamento e l'uso 7
ES
Instrucciones de puesta en marcha y funcionamiento
8
PT Instrões de arranque e operão 9
ET Käivitus- ja kasutusjuhised 10
DA Start- og driftsinstruktioner 11
FI Käynnistys- ja käyttöohje 12
EL Οδηγίεςεκκίνησηςκαιλειτουργίας 13
NL Start- en bedrijfstellingsaanwijzingen 14
NO Start- og driftsveiledning 15
BG
Ръководствозапусканевдействиеизаработа
16
CS
Pokynyprospuštěníaobsluhu
17
HR
Upute za puštanje u rad i kortenje
18
HU Indításiéskezelésiutasítások 19
LT
Užvedimoirnaudojimoinstrukcijos
20
LV Darbasākšanasunekspluatācijasnorādījumi 21
PL Instrukcja rozruchu i eksploatacji 22
RO
Instrucţiunidepornireşiutilizare
23
SI
Navodila za zagon in delovanje
24
SK
Pokynynaprevádzkuaobsluhu
25
TR
Çalıstırmaveişletmetalimatları
26
RU
Руководствопозапускуиэксплуатации
27
ZH
作说明
28

Other manuals for Sulzer XJ Series

Questions and Answers

  • N
    nbowersAug 13, 2025
    Why does the motor of my Sulzer XJ keep tripping out?
    • L
      Lauren YangAug 14, 2025
      If your Sulzer Water Pump's motor trips out, several factors could be responsible: * The pump might be rotating in the wrong direction, in which case you should shift phases. * The water temperature may be too high (exceeding 40 ºC), so check the water temperature. * The impeller could be blocked; inspect for obstructions like stones or pieces of wood. * Low voltage may be the issue, possibly due to long cables or an inadequate power supply (like a generator). Therefore, you should check the cables and power supply.
  • D
    Dr. Jesse Cabrera Jr.Aug 19, 2025
    How to troubleshoot a Sulzer Water Pump that will not start?
    • B
      Brian JohnsonSep 12, 2025
      If your Sulzer Water Pump won't start, consider these potential causes: * Check the power lines to ensure they are not dead. * Inspect the fuses and breakers to see if any have blown. * Verify that there is no phase failure. * Look for obstructions like stones or wood that may be blocking the impeller. * A service inspection is needed if there is a loose cable.
  • G
    gadamsAug 25, 2025
    What causes the Residual Current Device to trip in a Sulzer Water Pump?
    • J
      John GloverAug 25, 2025
      If the Residual Current Device (RCD) trips out, it may be due to moisture in the stator. In this case, the motor needs to be dried.
  • D
    Dr. Lori HernandezAug 29, 2025
    What to do if my Sulzer XJ Water Pump is operating at too low capacity?
    • S
      Stephen GravesAug 29, 2025
      If your Sulzer Water Pump is operating at too low capacity, it might be because of: * A clogged strainer, which requires cleaning the strainer. * Sharp bends, folds, or restrictions in the discharge hose, so adjust the hose. * A total delivery head (static head + friction losses) that is too high, which means you should exchange the pump for one with sufficient capacity for the task.
  • B
    billy18Sep 3, 2025
    Why is there water in the oil chamber of my Sulzer XJ Water Pump?
    • S
      Susan BatesSep 3, 2025
      If you find water in the oil chamber of your Sulzer Water Pump, it could be caused by: * A defective shaft seal, which means you should change the primary seal. * Faulty assembly of o-rings, mechanical seal, or upper diffuser, in which case you should replace the parts. * Worn seals, so replace the parts and dry the motor.
  • D
    Donna MacdonaldNov 8, 2025
    What to do if water is inside the top cover or motor housing of my Sulzer XJ Water Pump?
    • J
      Justin BatesNov 8, 2025
      If water is found inside the top cover and/or motor housing of your Sulzer Water Pump, it could be due to several reasons: * A damaged or cut pump cable, which requires a cable replacement. * A loose cable gland or a faulty assembly of the gland, which means you should replace the cable gland and cable seal. * A damaged o-ring, foreign material between the motor housing and jacket, or cover, suggesting a complete pump overhaul and replacement of damaged parts. * Pinched wires between the top cover and main cover, indicating the need to replace damaged wires and check the contactor. * Loose or missing screws securing the top cover to the main cover, necessitating a complete pump overhaul and replacement of missing parts. * Water entered through the inspection hole, meaning you ...