Page 12 MPE-200 Guide to Operations
4. EQUALIZER SECTION
Channel B LF filter off (amber), set for shelving,
preset unlocked, with 9.5 dB added at 35 Hz
4.1 EQUALIZER OVERVIEW
The MPE-200 has four bands of Eq, each of which can be selected
either ON (green) or OFF (amber) by pressing each display. The
on/off state of each Eq band is also shown by the lock icons on its
display. A lock icon on the left of the display refers to the “A”
channel, with the state of the “B” channel shown on the right. When
off, the filter circuit is completely removed from the signal path.
4.2 BOOST / CUT CONTROL
The Eq Boost/Cut control is to the right of each filter display. The
range is ±16 dB, in coarse (2 dB) steps or fine (0.5 dB) steps.
Pressing the encoder knob switches between coarse and fine control,
and the LEDs below the knob show the current control mode.
4.3 FREQUENCY CONTROL
Frequencies are selected by rotating the encoder knob below each
Eq display. For High and Low Eq, peaking or shelving can be
selected by pressing the frequency knob. In either case, the filter
slope is fixed at 12 dB/octave.
2
+9.5
35 Hz