Page 20 MPE-200 Guide to Operations
8. FUSE AND VOLTAGE SELECTION
The main fuse and the voltage selector are part of the Power Entry
module on the rear panel of the MPE-200, where the power cord
connects. The fuse will only fail if there is a circuit fault. If the
MPE shuts down unexpectedly, or fails to turn on, first confirm
that it is connected to a source of the correct voltage.
CAUTION: Disconnect the power cord from the MPE
before attempting fuse inspection or voltage selection!
ATTENTION:
DEBRANCHER AVANT DE REMPLACER LE
FUSIBLE.
8.1 FUSE INSPECTION OR REPLACEMENT
Remove the rectangular fuse holder by gently prying at the notch
provided with a small screwdriver or paper clip. Use only slow-
blow 5x20 mm. fuses of these types and values:
For 90-125 volt, use two 0.8 amp fuses type IEC 127-2
For 200-250 volt, use two 0.4 amp fuses type IEC 127-2
ATTENTION:
UTILISER UN FUSUBLE DE RECHANGE DE MEME TYPE DE
0.8A - 90-125v, 0.4A - 200-250v.
The fuse should only fail if there is an internal circuit fault in the
MPE-200. If you find a blown fuse, please contact Summit Audio
Customer Service before attempting replacement.
!
!
!
!
!
!