Installation, Operation, and Maintenance Manual
SUMMIT PUMP MODEL SP 8
4. OPERATION
CHECKING ROTATION
CAUTION!
Lock out power to avoid personal injury.
WARNING!
Operating the pump in the opposite
direction may cause damage to casing and
impeller
1. Lockout power to drive.
2. Remove coupling guard.
3. Remove coupling grid/sleeve element so that the motor half of coupling can spin
free from the pump half.
4. Unlock power to motor.
5. Clear personnel from immediate area, jog motor just enough to determine
direction of rotation. Rotation must be same as arrow on pump.
6. If same, lock out pump, reassemble coupling grid/sleeve to connect pump half.
7. If direction is wrong, change electrical wiring connection and repeat Step 4, 5 and
6.
8. Install coupling guard
9. Unlock motor, pump is ready to run.
LUBRICATION
Summit SP pumps are grease lubricated. The pump has been pre-greased at the factory
for 2000 hours operation. Regreasing should occur at 2000 hours or at three month
intervals.
Acceptable greases are shown in the table below:
Table 5
Acceptable Greases
Citgo Mystic EP2
Keystone 81EP2
Mobil Mobil Grease XHP222
Mobil Synthetic SCH 100