Installation, Operation, and Maintenance Manual
SUMMIT PUMP MODEL SP 3
2. RECEIPT AND STORAGE
RECEIVING THE PUMP
Immediately upon arrival, carefully inspect the pump for evidence of damage during
transit. Immediately report any damage to your local Summit Pump distributor.
STORING THE PUMP
TEMPORARY
Temporary storage is less than six months. Store pump in a clean, dry place, free from
extreme swings in temperature and humidity. Rotate the shaft once a week to avoid
bearing damage.
LONG TERM
Long Term Storage is more than six months. Follow temporary storage guidelines and
consult with factory for detailed long term guidelines.
HANDLING
Pump unit boxes and crates may be unloaded using a forklift or slings depending on size
and package construction.
WARNING!
Pumps and assemblies are heavy, improper
handling can result in serious injury.
LIFTING
To avoid damage to pump and/or motor unit should be lifted using a nylon sling, chain or
wire rope. The slings should be placed so lift is equally supported at four or more points.
To avoid damage, See figure below to guide placement of slings.
CAUTION!
Be sure all components are securely
fastened to baseplate before lifting.
DO NOT LIFT
FROM THIS POINT
CORRECT INCORRECT