Chapter 3 Sun Storage J4200/J4400 Specifications 21
Electrical Requirements
This section provides information regarding site power and wiring, module AC
power requirements, and power cord routing instructions.
Site Wiring and Power
The tray uses wide-ranging redundant power supplies that automatically
accommodate voltages to the AC power source. The power supplies operate within
the range of 100 VAC to 240 VAC, at a minimum frequency of 47 Hz and a maximum
frequency of 63 Hz. The power supplies meet standard voltage requirements for
both domestic (inside USA) and international (outside USA) operation. They use
standard industrial wiring with line-to-neutral or line-to-line power connections.
Power Input
The AC power sources must provide the correct voltage, current, and frequency
specified on the tray model and serial number label. The tray can run without
interruption within the limits shown in
TABLE 3-8 and TABLE 3-9.
.
TABLE 3-8 J4200 Tray AC Power Requirements
Condition Specification
AC power 9 A maximum operating (100 VAC to 127 VAC
range), 47 to 63 Hz
4.5 A maximum operating (200 VAC to 240
VAC range), 47 to 63 Hz
Maximum operating current 1.51 A maximum operating @ 240 VAC (198
VAC to 264 VAC range), 50 to 60 Hz
TABLE 3-9 J4400 Tray AC Power Requirements
Condition Specification
AC power 10 A maximum operating @ (100 VAC to 127
VAC range), 47 to 63 Hz
Maximum operating current 27.4 A maximum operating @ 240 VAC (198
VAC to 264 VAC range), 50 to 60 Hz