Functional Details 53
E500 Series Universal Low-Power Inverter
The automatic voltage regulation function is for protecting inverters voltage
from fluctuating with input voltage fluctuation. When the grid voltage varies
greatly and it desired that the motor has comparatively stable stator voltage and
current, this function should be enabled.
0: invalid 1: Deceleration time is invalid 2: Effective
This parameter is mainly used to calculate motor revolution.
6.4 Multi-speed and senior running parameter group
It is to set terminals with this parameter function code to control multi-speed
running output frequency.
This parameter is used to set the running liner speed and display value of liner
speed. It can be also used to display other physical quantity proportional to
output frequency.
F3.00 Multi-speed frequency 1 Setting range: 0.0Hz ~ Upper limiting frequency
F3.01 Multi-speed frequency 2 Setting range: 0.0Hz ~ Upper limiting frequency
F3.02 Multi-speed frequency 3 Setting range: 0.0Hz ~ Upper limiting frequency
F3.03 Multi-speed frequency 4 Setting range: 0.0Hz ~ Upper limiting frequency
F3.04 Multi-speed frequency 5 Setting range: 0.0Hz ~ Upper limiting frequency
F3.05 Multi-speed frequency 6 Setting range: 0.0Hz ~ Upper limiting frequency
F3.06 Multi-speed frequency 7 Setting range: 0.0Hz ~ Upper limiting frequency
F3.07 Liner speed coefficient setting Setting range
0.01 ~ 100.00
F2.17 Reserve
F2.18 Automatic voltage regulation Setting range: 0~2
F2.19 Pairs of motor polarity Setting range: 1~16
F2.20~F2.21 Reserve