EasyManua.ls Logo

Sunfar E500-2S0015(B) - User Manual

Default Icon
103 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Preface
Thanks for choosing the E500 series universal low-power inverter produced
by Shenzhen Sunfar Electric Technologies Co., Ltd.
This Manual is the operating manual for E500 series universal low-power
inverters. It
provides all relevant instructions and precautions for installation,
wiring, functional parameters, daily care and maintenance, fault diagnosis and
troubleshooting
of E500 series inverters.
In order to use this series of inverters correctly, guarantee product's best
performance and ensure safety of users and equipment, be sure to read this
manual carefully before using E500 series inverters.
Improper use may cause
abnormity and malfunction of the inverter, reduce its service life and even
damage equipments and lead to personal injury and death etc.
This user manual is delivered with the device. Please keep it properly for
future overhaul and maintenance.
Owing to constant improvement of products, all data may be changed without
further notice.
SHENZHEN SUNFAR ELECTRIC TECHNOLOGIES CO., Ltd.
User Manual of E500 Series Universal Low-Power Inverter
Version V1.0
Revision Date: Mar. 2015
HRW Limited
admin@hrw.hk
www.hrw.hk
Question and Answer IconNeed help?

Do you have a question about the Sunfar E500-2S0015(B) and is the answer not in the manual?

Summary

Precautions

2. Safety precautions

Guidelines for safe operation, installation, and maintenance.

2.2 Wiring

Instructions and precautions for connecting the inverter's wiring.

Product Introduction

1.4 Product technical indicators and specifications

Detailed technical specifications and performance indicators of the E500 series.

Inverter Installation

2.1 Environmental requirements

Conditions for the installation environment to ensure optimal performance and safety.

Inverter Wiring

3.1 Wiring precautions

Critical safety and connection guidelines for inverter wiring.

3.4 Wiring of main loop terminal

Specific wiring instructions for the main power loop terminals.

3.5 Wiring of control loop terminal

Details on connecting the control loop terminals and their functions.

Operating Panel

4.1 Function description of keys

Explanation of the function and purpose of each key on the operating panel.

4.2 Panel operating method

Step-by-step guide for navigating and operating the inverter via the panel.

Function Parameter Table

Fault Diagnosis And Countermeasures

7.1 Protection function and countermeasures

Table of fault codes, causes, and solutions for inverter protection functions.

7.3 Fault reset

Procedures for resetting the inverter after a fault condition.

SUNFAR Self-Defined Communication Protocol

MODBUS Protocol Specification

Sunfar E500-2S0015(B) Specifications

General IconGeneral
Power1.5 kW
Efficiency98%
Frequency0 Hz - 400 Hz
Protection FeaturesOverload, Overvoltage
Input Voltage220-240 V AC

Related product manuals