EasyManuals Logo

Sunfar E500-2S0015(B) User Manual

Default Icon
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
20 Function Parameter Table
E500 Series Universal Low-Power Inverter
5 Function Parameter Table
Parameter
Type
Function
Code
Name
Setting Range and
Description
Minimum
unit
Default
setting
Modifica-
tion limit
Basic running parameter group
F0.00
Frequency
input channel
0: Digital setting
1: External analog
quantity
2: External
communication
3: Panel
potentiometer
4: Selection of
external terminal
5: Combined setting
1 3
F0.01
Frequency
digital setting
0.0Hz ~ Upper
limiting frequency
0.1 0.0
F0.02
Selection of
running
command
channel and
mode
LED Units:
Selection of running
command channel
0: Keyboard control
1: External terminal
control
2: communication
port
LED Tens: Running
command mode
selection
0: Two-line mode 1
1: Two-line mode 2
2: Three-line mode
3: Special mode for
terminal machine
LED Hundreds:
REV prevention
0: REV prevention
void
1: REV prevention
effective
LED Kilobit:
Power-on auto start
0: Power-on auto
start forbidden
1: Power-on auto
start allowed
1 1000
F0.03
Lower limiting
frequency
0.0Hz ~ [F0.04] 0.1 0.0
F0.04
Upper limiting
frequency
[F0.03] ~ 1000Hz 0.1 50.0
F0.05
Acceleration
time
0.1 ~ 600.0 Sec 0.1 5.0
F0.06
Deceleration
time
0.1 ~ 600.0 Sec 0.1 5.0
HRW Limited
admin@hrw.hk
www.hrw.hk

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sunfar E500-2S0015(B) and is the answer not in the manual?

Sunfar E500-2S0015(B) Specifications

General IconGeneral
BrandSunfar
ModelE500-2S0015(B)
CategoryInverter
LanguageEnglish

Related product manuals