Inverter Wiring 13
E500 Series Universal Low-Power Inverter
3.4 Wiring of main loop terminal
Category I main loop terminal
Applicable models :
E500-2S0004(B)~E500-2S0007(B)
大地
WPP
L1
PB E U V
220V
电源输入
制动电阻
电动机
L2
Symbol Function
PP DC side voltage positive terminal
PB
Braking resistor can be connected
between PP and PB
L1, L2
To grid single-phase AC 220V
power supply
U, V, W To three-phase AC 220V motor
E Earthing terminal
Category II main loop terminal
Applicable models :
E500-2S00015(B)~E500-2S0022(B) &
E500-4T00007(B)~E500-4T0022 (B)
大地
E
PB
T
PP
UVW
单相/三相
电源输入
制动电阻
电动机
L1
R
S
L2
Symbol Function
PP DC side voltage positive terminal
PB
Braking resistor can be connected
between PP and PB
L1
R
,
L2
S
, T
To grid single-phase AC 220V/
three-phase 380V power supply
U, V, W
To three-phase AC 220V/380V
motor
E Earthing terminal
Category III main loop terminal
Applicable models :
E500-2S0030 (B)~E500-2S0040(B) &
E500-4T00030(B)~E500-4T0040(B)
大地
E
PB
L2
T
PP
UVW
单相/三相
电源输入
制动电阻
电动机
L1
S
R
Symbol Function
PP
DC side voltage positive terminal
PB
Braking resistor can be connected
between PP and PB
L1
R
,
L2
S
, T
To grid single-phase AC 220V/
three-phase 380V power supply
U, V, W
To three-phase AC 220V/380V
motor
E Earthing terminal
Power supply input
Braking resistor
Earthing
Earthing
Braking
resistor
Earthing
Moto