3.2、Mount the inverter
Punch 4 mounting holes in the wall with an electric drill according to the specified size, and insert 4
M8*60 expansion screws above.
3.3、Remove the terminal cover & anti insect net
Using a screwdriver, remove the terminal protection cover and anti-insect net.
When using the device in areas with poor air quality, the fan cover is easily blocked by air
particles. Please disassemble and clean the fan periodically to avoid affecting the internal air
flow rate of the inverter, which may trigger an over-temperature protection fault (19/20 fault)
affecting the use of the power supply and the service life of the inverter.