5.2、Setting
Operating Instructionstap settings in the menu bar at the bottom of the screen to enter the settings
interface, including Basic setup, Work mode setup, Battery setup On grid setup and Advance setup.
Parameter settings:
Parameter Meaning
Options
Description
Basic setup
System date
This item shows the inverter date, click on it to set the date
System time
This item shows the inverter time, click on it to set the time
Beep
You can choice whether enable the Beep alarm
Password input
Input the inverter password, default password:000000
Password setting
You can set the inverter password
RS485 Address
Displays the current inverter 485 address and jumps to the 34 setting item when clicked.
Display setup
Set the Screen brightness
Set language
Work Mode
Off/on grid mode
Off grid
Off grid mode
On grid
The excess solar energy will feed back into the grid directly
Anti-feed power
to AC in port
Hybrid inverter will only provide power to the backup load
connected. The hybrid inverter will neither provide power to
the home load nor sell power to grid.
Anti-feed power
to grid entry
Hybrid inverter will not only provide power to the backup load
connected but also give power to the home load connected. If
PV power and battery power is insufficient, it will take grid
energy as supplement. The hybrid inverter will not sell power
to grid. In this mode, a CT is needed.
output source priority
AC first
Utility priority: switch to inverter only when utility power is not
available.
Battery first
Inverter priority: switch to mains only when the battery is
under-voltage or below the value set in parameter”
Turn To
Inverter Volt” or ”Switching to utility SOC”.