Turn To Inverter Volt
56.8V default
When output source priority is Solar first or battery first,
output source will switch to battery from utility when the
battery voltage above the preset value. Range:40~60V
Battery SOC to line
10%
Switch to utility power when the battery SOC is less than this
setting
Battery SOC to inverter
100%
Switches to inverter output mode when SOC is greater than
this setting
Battery curr. stop chg.
3 default
Charging stops when the charging current is less than the set
value
Batt. SOC low alarm
15%
Triggers an alarm when the battery SOC is less than the set
value
Batt. SOC stop dchg.
5%
Stops discharging when the battery SOC is less than the set
value
Bat. SOC stop chg.
100%
Stops charging when the battery SOC is touch the set value
On grid setup
Grid standard
European general:EN50549
Select the the local grid standard
UK:G99
South Africa:NRS-097
Grid frequency
50HZ default
Select the inverter output frequency
60HZ
On grid max power
When the off/on grid mode “is “On grid”,you can set the max on-grid power(less than
the inverter rated power)
Advance setup
CT ratio
1000
Select the CT ratio
2000
4000
zero-export power
20W default
for zero-export mode, it tells the grid output power.
Recommend to set it as 20-100W to ensure the hybrid inverter
won' t feed power to grid.
PE-N connect disable
Disable
Disable PE-N Automatic switching
Enable
Enable PE-N Automatic switching
Output voltage setting
230Vac default
Setting range: 200/208/220/230/240Vac
Generator charging
current
40A default
Setting range 0~60A
Oiler power setting
5Kw default
Set the input power of the generator to not exceed the rated
power of the inverter
PV insulation
impedance testing
Disable default
Disable PV insulation impedance testing
Enable
Enable PV insulation impedance testing (ISO)