When output source priority is Solar first or battery first,
output source will switch to battery from utility when the
battery voltage above the preset value. Range:40~60V
Switch to utility power when the battery SOC is less than this
setting
Switches to inverter output mode when SOC is greater than
this setting
Charging stops when the charging current is less than the set
value
Triggers an alarm when the battery SOC is less than the set
value
Stops discharging when the battery SOC is less than the set
value
Stops charging when the battery SOC is touch the set value
Select the the local grid standard
Select the inverter output frequency
When the “ off/on grid mode “is “On grid”,you can set the max on-grid power(less than
the inverter rated power)
for zero-export mode, it tells the grid output power.
Recommend to set it as 20-100W to ensure the hybrid inverter
won' t feed power to grid.
Disable PE-N Automatic switching
Enable PE-N Automatic switching
Setting range: 200/208/220/230/240Vac
Generator charging
current
Set the input power of the generator to not exceed the rated
power of the inverter
PV insulation
impedance testing
Disable PV insulation impedance testing
Enable PV insulation impedance testing (ISO)