9 Troubleshooting and Maintenance User Manual
58
9.2 Maintenance
9.2.1 Routine Maintenance
Items Methods Period
System clean
Check the temperature and dust of the inverter.
Clean the inverter enclosure.
Check the humidity and dust of the environment.
Meanwhile check whether the filter function of
the air inlet is ok. Clean the air inlet and outlet,
when necessary.
Six months to a
year (it
depends on the
dust contents
in air.)
Fans
Check whether there is crack of the fan blade
Check whether there is any abnormal noise of the
fan turning.
Clean or replace the fans.
Once a year
9.2.2 Maintenance Instruction
Disconnect the inverter from the grid first and then PV arrays before any
maintenance work.
Lethal voltage still exists in the inverter. Please wait at least ten minutes
and then perform maintenance work.
Cleaning Fan
There are four fans in the inverter for ventilation. It is recommended that the fans
are cleaned every six months.
Step 1 Disconnect the output and input side.
Step 2 Wait for at least ten minutes.
Step 3 Dismantle the inverter in the reversed direction of “Installation procedure.
Step 4 Loosen the fixed screws on the back of the inverter.
Step 5 Clean the fan with soft brush or vacuum cleaner.
Step 6 Reinstall the inverter.
Step 7 Re-connect the inverter.
Step 8 Restart the inverter.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG20KTL and is the answer not in the manual?

Sungrow SG20KTL Specifications

General IconGeneral
ModelSG20KTL
TypeString Inverter
Rated Output Power20 kW
Max. DC Input Power30 kW
Max. DC Input Voltage1100 V
Start Voltage200 V
Number of MPPTs2
Max DC Input Current per MPPT26 A
Max. Input Current per MPPT26 A
Rated AC Power20 kW
Rated AC Voltage400 V
AC Voltage Range310 V - 480 V
Rated Grid Voltage400 V
Rated Grid Frequency50 Hz / 60 Hz
Total Harmonic Distortion< 3%
Power Factor at Rated Power1
Adjustable Power Factor Range0.8 leading - 0.8 lagging
Max. Efficiency98.6%
European Efficiency98.4%
Efficiency98.6%
DC SwitchYes
Protection ClassIP65
Cooling ConceptNatural Cooling
Max. DC Power22000 W
Max. AC Power22 kW
Grid Frequency50/60 Hz
Operating Temperature Range-25 °C ~ +60 °C
Input Voltage Range200 V - 1000 V