User Manual 9 Troubleshooting and Maintenance
73
Leakage current
over-current.
The leakage current
exceeds inverter
allowable upper limit.
1. Check the PV strings for ground fault.
2. If the fault occurs repeatedly, contact
SUNGROW.
10-minute grid
over-voltage.
The average grid
voltage in 10 minutes
exceeds the
permissible range.
1. Check whether the selected country code
is correct.
2. Wait a moment for inverter recovery.
3. Check the voltage of the grid. If the grid
voltage exceeds the permissible range of
inverter protection parameters, ask utility
grid company for solution.
4. If the fault occurs repeatedly, contact
SUNGROW.
Grid over-voltage
The grid voltage
exceeds the protective
value, which is higher
than the protective
value of error 002.
(stage II)
1. Check the model of the AC cables.
2. Wait a moment for inverter recovery.
3. If the grid voltage exceeds the
permissible range, ask utility grid company
for solution.
4. If the fault occurs repeatedly, contact
SUNGROW.
The bus voltage or
power is high.
1. Wait a moment for inverter recovery.
2. If the fault occurs repeatedly, contact
SUNGROW.
Bus transient
over-voltage.
The transient bus
voltage exceeds
inverter allowable
upper limit.
1. Wait a moment for inverter recovery.
2. If the fault occurs repeatedly, contact
SUNGROW.
Bus over-voltage.
The bus voltage
exceeds inverter
allowable upper limit.
1. Wait a moment for inverter recovery.
2. If the fault occurs repeatedly, contact
SUNGROW.
Check the layout and the wiring of PV1
input.
Check the layout and the wiring of PV2
input.
Check the cable connections of PV1.
Check the cable connections of PV2.
The temperature of
radiator is too high.
1. Check whether the ambient temperature
shown on the screen is too high. Wait a