EasyManuals Logo

Sungrow SG2K5-S User Manual

Sungrow SG2K5-S
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #88 background imageLoading...
Page #88 background image
10 Appendix User Manual
80
Parameters
SG2K-S
SG2K5-S
SG3K-S
Power factor
>0.99 at default value at nominal power
(adj. 0.8 leading to 0.8 lagging)
Protection
PV reverse connection
protection
Yes
AC short circuit protection
Yes
Leakage current protection
Yes
Anti-islanding protection
Yes (frequency shift)
Low voltage fault ride
through (LVRT)
Yes (only for DE, NL, EU, “PL”, “IT”)
High voltage fault ride
through (HVRT)
Yes (only for DE, NL, EU, “PL”, “IT”)
DC switch
Yes
Overvoltage category
III [AC], II [DC]
Safety protection class
I
System Data
Max. efficiency
98.2 %
98.2 %
98.2 %
Max. European efficiency
97.2 %
97.5 %
97.7 %
Isolation method
Transformerless
Ingress protection rating
IP65
Pollution degree outside the
enclosure
3
Pollution degree inside the
enclosure
2
Power loss in night mode
< 1 W
Operating ambient
temperature
-25 ... +60 (derating when > 45)
Max. allowable value for
relative humidity
(non-condensing)
100 %
Cooling method
Natural cooling
Max. operating altitude
4000 m (derating when > 2000 m)
Display
Graphic LCD
Communication
Wi-Fi, Ethernet (optional)
PV connection type
MC4
AC connection type
Plug and play connector
Certification
IEC 61000-6-2, IEC 61000-6-3, IEC 62109-1,
IEC 62109-2, VDE-AR-N-4105, VDE0126-1-1
G83/2, C10/11, EN50438, EN50549-1:2019, CEI
0-21:2016-06
Mechanical Data
Dimensions (W x H x D)
300 mm x 370 mm x 125 mm
Mounting method
Wall-mounting bracket
Weight
8.5 kg

Table of Contents

Other manuals for Sungrow SG2K5-S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG2K5-S and is the answer not in the manual?

Sungrow SG2K5-S Specifications

General IconGeneral
BrandSungrow
ModelSG2K5-S
CategoryInverter
LanguageEnglish

Related product manuals