109
step 2 Dismantle the inverter referring to "5 Mechanical Mounting" in reverse steps.
step 3 If necessary, remove the wall-mounting bracket from the wall.
step 4 If the inverter will be reinstalled in the future, please refer to "4.3 Inverter Storage" for a prop-
er conservation.
- - End
9.1.3 Disposal of Inverter
Users take the responsibility for the disposal of the inverter.
Please scrap the inverter in accordance with relevant local regulations and stand-
ards to avoid property losses or casualties.
Some parts of the inverter may cause environmental pollution. Please dispose of
them in accordance with the disposal regulations for electronic waste applicable at
the installation site.
9.2 Decommissioning the Battery
Decommission the battery in the system after the inverter is decommissioned. Proceed as
follows to decommission a Li-ion battery.
step 1 Disconnect the DC circuit breaker between the battery and the inverter.
step 2 Disconnect the communication cable between the battery and the inverter.
step 3 Wait for about 1 minute and then use the multimeter to measure the port voltage of the
battery.
step 4 If the battery port voltage is zero, disconnect the power cables from the battery module.
- - End
For disposal of this product, please call the phone number listed in the warranty
booklet provided at the time of purchase.
User Manual 9 System Decommissioning