82
Network Service Provider Grid Type
Endeavour Energy
MDI 0043
Ausgrid
NS194
CitiPower & Powercor
• ≤ 5 kVA for single-phase & 30 kVA for
three-phase
• > 30 kVA three-phase
United Energy
• UE-ST-2008.1: ≤ 10 kVA for single-
phase & 30 kVA for three-phase
• UE-ST-2008.2: > 30 kVA three-phase
PowerWater
Embedded Generation Notice Photovoltaic
Systems:2020
SA Power Networks
• TS129-2019: < 10 kW for single-phase
& 30 kW for three-phase
• TS130-2017: > 30 kW & ≤ 200 kW
• TS131-2018: > 200 kW
Horizon Power
• HPC-9DJ-13-0001-2019: ≤ 10kVA for
single-phase & 30 kVA for three-phase
• HPC-9DJ-13-0002-2019: > 30kVA &
≤1MVA
westernpower
EDM#33612889-2019
AusNet Services Basic Micro Embedded Generation: 2020
* For compliance with AS/NZS 4777.2:2020, please select from Australia A/B/C. Please con-
tact your electricity grid operator for which region to use.
• Please check the country supported by this product at http:// support.sungrow-
power.com/.
• Set Country/Region to the country/region where the inverter is installed. Oth-
erwise, the inverter may report a fault.
step 10 After a plant is successfully created, return to the App home page to view the plant
information.
- - End
7 Commissioning User Manual