22
d) Tension adjustment of the take-up lever spring
If you unfasten the nut in the thread-adjusting device shaft and turn it clockwise at the face groove of the thread-adjusting device
shaft using a screwdriver, the tension of the take-up lever spring will become stronger, and weaker when turned counterclockwise.
e) Timing adjustment of the take-up lever spring
If you loosen the stopper screw and move the guide plate of the take-up lever spring in a clockwise direction, the operating timing
of the take-up lever spring will become faster, and slower when turned counterclockwise.
The standard operating timing of the take-up lever spring is when the stopper screw comes to position at the center of the guide plate .
[ Fig. 30 ]
[ Fig. 31 ]
Weak
Strong
c) Adjustment of the take-up lever spring
If you loosen the stopper clamp screw and turn the take-up lever spring stopper counterclockwise as shown in [Figure 29], the
moving range of the take-up lever spring will become larger, and when turned clockwise, smaller.
The standard moving range of the take-up lever spring is 5~10 mm.
[ Fig. 29 ]