37
19) Replacement of the gauge
A. Refer to the gauges shown in the SunStar Parts Manual when ordering a gauge for replacement.
B. Take out the gauge parts①~⑧ originally attached to the machine.
C. Unfasten clamp screws① and ② as illustrated in [Figure 63].
D. Loosen four fixing screws on the left and right of the hook base as shown in [Figure 64]
E. Mount the new feed dog and needle plate.
F. Insert the needle plate into the groove of the needle bar as explained in [Figure 65] and fasten the clamp screw
①.
G. Refer to the previous instruction for setting each gauge.
[ Fig. 63 ][ Fig. 62 ]
①
②
③
④
⑤
⑥
⑧
⑦
[ Fig. 65 ][ Fig. 64 ]
①
①
②
Caution
▶
Only qualified and trained technicians should change the gauge.
▶
Before replacing, always turn off the power switch and pull the power plug. If the operator
mistakenly steps on the pedal with the switch on, the machine will start automatically and can cause
injury.
※When using a clutch motor, be aware that the motor will continue to rotate for a while even after
the power is off due to inertia. Proceed to work after the motor has come to a complete stop.
▶
For gauge parts replacement, use parts specified by SunStar.