EasyManua.ls Logo

SunStar KM-1060BL - Setting Potentiometer

SunStar KM-1060BL
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
Press and button to move to parameter number 27
Turn the dial for adjusting presser foot lifting amount and set it
at 2.5 (mm)
Set at 2.5 (mm) and press the button. The screen will
automatically change with a buzzer sound
Set at 4.0 (mm) and press button. The screen will
automatically change with a buzzer sound
Set at 4.8 (mm) and press button to change the screen
with a buzzer sound
Turn the dial again to set at 4.0 (mm)
Turn the dial once again to set at 4.8 (mm)
After setting is complete, push button to go back to the
initial screen
󳢯Sewing initial screen
󳢯Initial screen for parameter group A
󳢯P1 setting screen for group A item 27
󳢯When dial is turned, the value will be displayed
on
󳢯When dial is turned, the value will appear
on
󳢯When dial is turned, the value will be displayed
on
󳢯P2 setting screen for Group A item 27
󳢯P3 setting screen for group A item 27
󳢯Setting is complete
󳢯Sewing initial screen
2) Setting potentiometer
󳥃󳥃
How to set
󳥃󳥃
Relation between presser foot lifting amount and maximum speed of the sewing machine
When setting each step of P1, P2 and P3, be sure to press button to save the set value. Otherwise, the set value will not be saved.
The
▶▶
sign from screen 3 to 8 in the above table may vary to some degree depending on the location of the installed potentiometer.
If you turn off the power before completing step 9, you will have to start over again.
The set value of the potentiometer will be erased if you initialize. Initialize only when it is necessary. Remember that you have to reset
the potentiometer after initialization.
If the potentiometer connector is not linked or the cable is cut, OV will be displayed on the screen.
Presser foot lifting amount
1.0 - 2.5 mm
2.5 - 4.0 mm
4.0 - 4.8 mm
4.8 - 7.0 mm
Maximum speed of the sewing machine
3500 spm
3000 spm
2500 spm
2000 spm (adjustable from group A item 20)
DetailsScreen displayHow to operate
Turn on the power
Press button, then press button while holding down
button to change screen
Sequence
1
2
3
4
5
6
7
8
9
10

Table of Contents

Related product manuals