48
[ Warning ]
Before adjustments, always turn off the motor switch and check to make sure that the motor is in stop mode.
The fixed blade body ⒃ simultaneously moves to the
left with the moving fixed body ③ and stops after
contacting the stopper for fixed blade body ⒔. At this
point, the fixed blade will slide under the needle plate
and begin to move.
(6) Position of fixed blade body
A. Unfasten the screw ⒕.
B. Set a clearance of 1mm between the left end tip of the
thread trimming base ⒖ and the left end tip of the
stopper for fixed blade body ⒔.
C. Adjust the screw ⒕ afterwards.
[ Figure 77 ]
⒃
⒔
⒕
⒖
③
1mm
[ Warning ]
Do not force the fixed blade body ⒃ to the left for the
clamp spring pressure can touch the looper.