67
The left mes driving should be divided in the following
order :
(1) Loosen the screws④ for the fixed mes (left mes).
(2) Move the fixed mes (left mes) 5mm downward from the
upper side of the needle plate.
(3) Tighten the screws④ again.
(4) Loosen the screws⑤ for the fixed mes (left mes)
holder and smoothly push the end of the moving mes
(left mes) holder③.
(Push until contact with the fabric guide⑥.)
(5) Close the cover⑦.
(6) Close the upper cover⑧.
(7) Loosen the screws for the suction pipe cover①.
(8) Move the suction pipe cover① to the right and fill the
space.
(9) Loosen the screws② for the suction pipe cover①.
※ Reassemble the meses following the above procedures in
the reverse order.
10) Separation of the left mes driving
[ Figure 116 ]
③
④
⑤
[ Figure 117 ]
[ Figure 118 ]
⑥
⑦
①
①
②
②
⑧
Turn off the motor switch before making any adjustments. Make sure that the motor is completely
turned off.
Warning