5.0) SPECIFICATIONS
Model No.
Btu/hr
High
Input
(2-stage)
Btu/hr
Low
Input
Air Plate
Part #
Orifice Size
Minimum *
Mounting Height
Turbulator
Qty.
Natural Gas
Propane Gas
@
Horizontal
@
45º Angle
SPS/SPU 40
40,000
25,000
44140061
#32
(0.116)
#49
(0.073)
10 ft.
9 ft.
4
SPS/SPU 50
50,000
30,000
44140064
3.5mm
(0.138)
46
(0.081)
11 ft.
10 ft.
5
SPS/SPU 75
75,000
50,000
44140063
#21
(0.159)
2.5mm
(0.098)
13 ft.
12 ft.
5
SPS/SPU 100
100,000
65,000
44140062
#12
(0.189)
#32
(0.116)
14 ft.
13 ft.
3
SPS/SPU 125
125,000
80,000
44140066
#4
(0.209)
#30
(0.129)
14 ft.
13 ft.
7
SPS/SPU 150
150,000
100,000
44140067
“A”
(0.234)
#27
(0.144)
15 ft.
14 ft.
4
SPS/SPU 175
175,000
110,000
44140067
“E”
(0.250)
#23
(0.154)
16 ft.
15 ft.
0
SPS/SPU 200
200,000
125,000
44140068
6.9mm
(0.272)
4.1mm
(0.161)
18 ft.
16 ft.
1
* MOUNT HEATERS AS HIGH AS POSSIBLE. Minimums are shown as a guideline for human comfort and uniform
energy distribution for complete building heating applications. Consult your SunStar representative for the
particulars of your installation requirements.
Model Identification:
Control Option
Suffix
Gas Type
Description
N5
Natural
Single Stage Gas Valve Single Stage Input
L5
Propane
Single Stage Gas Valve Single Stage Input
N7
Natural
Two Stage Gas Valve Modulating Input High/Low Fire
L7
Propane
Two Stage Gas Valve Modulating Input High/Low Fire
Type
Gas
Gas Pipe
Connection
Tube
Diameter
Flue
Connection
1
Fresh Air
Connection
1
Electrical
Supply
Current
Rating
Natural
or Propane
½” MPT
(Male)
4”
4” Round
4” Round
120 Volt, 60Hz,
1 Phase
1.74 Amp
1
See Section 16.0) for vent sizes when multiple heaters are connected into a common vent
Module Electrical Rating:
Ignition System (direct spark):
Input-Control: 18-30 VAC 50/60 Hz (class 2 transformer)
Input Power-Line: 120 VAC (L1, IND contacts only)
Flame Sensitivity: 0.7 uA (microamps) minimum
15 second trial for ignition period
15 second pre-purge period
60 second inter-purge period
30 second post-purge period
3 tries for ignition (separate flame sensor).
6.0) PACKING LIST
A. SPS/SPU Burner Package
Part Description QTY
Burner Box Assembly (Refer to the following chart for Package Part Numbers) .......................... 1
4”ID x 4”Lg Flue Adapter Collar (#30504500) .................................................................................. 1
Fastener Kit Burner Box Attachment/Flue Adapter Collar (#42907040) .................................. 1
Containing: #10 x 1/2” Self-Drilling Screws (#02189020) .................................................... 2
¼ - 20 Locknuts (#02167010) .............................................................................. 3
Tube Flange Gasket (#42921000) ........................................................................... 1
Turbulator 24” Long (#44152240) *See chart above for required quantities. .............................. *
Installation & Operation Instructions .................................................................................................... 1
Turnbuckle (#43343320) ......................................................................................................................... 1
Gas connector 5/8” OD x 36” (#30302360) US only ....................................................................... 1
Screen Assembly 2-5/8” ID x 5-1/2” Long (#44151010) 200M BTU models only ....................... 1
End Reflector Package (#43341000) ................................................................................................... 1

Table of Contents

Other manuals for SunStar SPS SERIES

Related product manuals