12-2
Error Type Cause
Incorrect position of needle
stop
Failure to sense signals for
needle position or 1 rotation
Incorrect position of needle
bar
Incorrect position of take-up
lever
Bad connection
Inspection & Repair
Refer to users manual
Run manual color change and
check if signal lamps (needle
set lamp & needle position
lamp) blinks at correct needle
position. Adjust the half-turn
film.
Set it to the correct position
Adjust so take-up lever is in
line with other levers in stop
position (upper shaft
angle:100°)
Change fuse F3 in joint board
or check connection
Set main shaft angle back at
100°, if you manually moved
it for cleaning, inspection or
repair.
See 11-9)
Adjusting position of
take-up lever
Unscrew the lever and
adjust so it is in line with
other take-up levers on
the guide rail.
Check fuse spec.
See 9-1)
Reference
Bad Color
Change
take-up
lever
screw
take-up
lever