EasyManua.ls Logo

SunTech ST3340 - Page 19

SunTech ST3340
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ST3340 User Manual
19
Recommend : 600 ( 10 min.)
MOTION_THRES String Step Detection level of shock violation.
Range : 0.04 ~ 2.0
Recommend : 0.04
SHOCK_THRES String Step Detection level of shock violation.
Range : 0.04 ~ 2.0
Recommend : 0.04
COLL_THRES String Step Gravity for collision report.
Range : 0.1 ~ 2.0
Recommend : 0.7
VI_ON_THRES String 1/255G Threshold value for Motion Virtual Ignition On
Range : 3~50
Default : 5
VI_ON_DELAY String Sec. Delay time for Motion Virtual Ignition On
Range : 3~999
Default : 10
VI_ON_PERCENT String % Percent for Motion Virtual Ignition On.
Range : 30~100
Default: 70
VI_OFF_THRES String 1/255G Threshold value for Motion Virtual Ignition Off
Range : 3~50
Default : 5
VI_OFF_DELAY String Sec. Delay time for Motion Virtual Ignition Off
Range : 3~999
Default : 10
VI_OFF_PERCENT String % Percent for Motion virtual Ignition Off.
Range : 30 ~ 100
Default : 70
<example>
[command] ST3340MSR;;02;600;0.04;0.04;0.7;5;10;70;5;10;70
[response] ST3340MSR;Res;852588;128;600;0.04;0.04;0.70;5;10;70;5;10;70
<notes>
* For the shock level, we recommend it to set to 0.04. if it's over than 0.04, the sensor will be more
insensitive
as it for shock detection.