Recommend : 0.7
VI_ON_THRES String 1/255G Threshold value for Motion Virtual Ignition On
Range : 3~50
Default : 5
VI_ON_DELAY String Sec. Delay time for Motion Virtual Ignition On
Range : 3~999
Default : 10
VI_ON_PERCENT String % Percent for Motion Virtual Ignition On.
Range : 30~100
Default: 70
VI_OFF_THRES String 1/255G Threshold value for Motion Virtual Ignition Off
Range : 3~50
Default : 5
VI_OFF_DELAY String Sec. Delay time for Motion Virtual Ignition Off
Range : 3~999
Default : 10
VI_OFF_PERCENT String % Percent for Motion virtual Ignition Off.
Range : 30 ~ 100
Default : 70
<example>
[command] ST4345MSR;;02;600;0.04;0.04;0.7;5;10;70;5;10;70
[response] ST4345MSR;Res;852588;128;600;0.04;0.04;0.70;5;10;70;5;10;70
<notes>
* For the shock level, we recommend it to set to 0.04. if it's over than 0.04, the sensor will be more
insensitive
as it for shock detection.
4-11. Control Command
HDR DEV_ID VER CMD_ID
● Definition : Controls some functions.
Field Definitions Unit Remark
HDR “ST4345CMD” Command type
DEV_ID 6 char. Device ID