Model NTX 3000 NTX 4000 NTX 5000 NTX 6000
Efficiency
Peak inverter efficiency
CEC weighted efficiency at 208 V
CEC weighted efficiency at 240 V
CEC weighted efficiency at 277 V
97.6% 97.7% 97.8% 97.8%
96.5% 97.0% 97.0% 96.5%
97.0% 97.0% 97.0% 97.0%
97.0%
Ambient condition
Ambient Temperature range
Relative humidity
-13°F...+140°F (-25°C...+60°C)
0…95%
Mechanical data
Width x height x depth
Weight
Noise emission
380 / 580 / 203 mm (15 /23.8/8 in)
57.3 lbs. (26 kg) 60.6 lbs. (27.5 kg) 64 lbs. (29 kg) 66 lbs. (30 kg)
< 40 dB (A)
General data
Inverter technology
Cooling concept
True sine, transformerless
Natural Natural Natural Programmable
convection convection convection forced active
cooling
10.4 Trip limits/trip times
Default values of output voltage and frequency are
standard values. User can adjust according to the
requirement.
Nominal frequency Trip limit Trip times
60 Hz > 60.5 Hz 0.01 s
Adjustable 57.0 Hz~59.8 Hz
(default 59.3 Hz)
Adjustable 0.16 s~300 s
(default 0.16 s)
< 57.0 Hz 0.083 s