8 Detailed parameter
Table 8.1 System parameter
Item Parameter Note
Module model B051100P01
Rated voltage 51.2V
Rated energy 5kWh
System Model Atrix basic-5
Atrix basic-10
Atrix basic-15
Atrix basic-20
Parallel No. 1 2 3 4
Rated energy 5kWh 10kWh 15kWh 20kWh
Rated charging
and discharging
current for
system
50A 100A 150A 200A
Max. charging
and discharging
current for
system
100A 180A 200A 200A
Rated voltage 51.2V
Working
voltage range
44.8V~55.2V
Communication
CAN
Protection
function
Charging over voltage, discharging under voltage, over current,
over temperature, short circuit protection
Cycle life
6000 cycles (25, 0.5C, 90%DOD, EOL 70%)
Scalability
Maximum 4 module parallel for one cluster;
Maximum 2 clusters parallel with combiner bus-bar
Enclosure
protection
rating
IP20
Working
ambient
temperature
Charging: (0,50]
Discharging: (-20,50]
Working
ambient
humidity
10%~95%RH
Altitude <4000m, Derating above 2000m
Certificate IEC62619,CE,UN38.3