Trap Logging
Critical
MAC Address table update
l
ogging
Disabled
Facility
Local0
1.7.1 Enable/Disable Syslog
Syslog is enabled by default in Supermicro switches.
Follow the steps below to disable Syslog.
Step Command Description
Step 1
configure terminal
Enters the configuration mode
.
Step 2
logging disable
Disable
s
Syslog.
Step 3
end
Exits the configuration mode.
Step 4
show logging
Displays the Syslog
configuration.
Step 5
write
startup
-
config
Optional step
saves this configuration
to be part of the startup configuration.
The
logging enable
command
enables the
Syslog
f
eature
.
The example below shows the commands used to disable Syslog.
SMIS# configure terminal
SMIS(config)# logging disable
SMIS(config)# end
SMIS# show logging
System Log Information
----------------------
Syslog logging: disabled(Number of messages 0)
Console logging: disabled(Number of messages 0)
File logging: disabled(Number of messages 0)
Log File Name:
File Max Entries: 500
TimeStamp option: enabled
Trap logging: Critical
Log server IP: None
Facility: Default (local0)