11
Chapter 1: Introduction
1.4 Server Chassis Features
Control Panel
The switches and LEDs located on the control panel are described below. See Chapter 4 for
details on the control panel connections.
Figure 1-1. Control Panel View
1 765432
Control Panel Features
Item Feature Description
1 Information LED See the following table for the status shown by this LED.
2 NIC2 LED 
3 NIC1 LED 
4 HDD LED 
5 Power LED
Indicates power is being supplied to the system power supply. This LED should
normally be illuminated when the system is operating.
6 Reset Button The reset button is used to reboot the system.
7 Power Button
The main power button is used to apply or remove power from the power supply
󰀨
but maintains standby power. To perform many maintenance tasks, you must
also unplug system before servicing.
Information LED
Status Description
Continuously on and red An overheat condition has occurred. (This may be caused by cable congestion.)
Blinking red (1 Hz) Fan failure: check for an inoperative fan.
Blinking red (0.25 Hz) Power failure: check for an inoperative power supply.
Solid blue Local UID has been activated. Use this function to locate the server in a rack environment.
Blinking blue (300 msec) Remote UID has been activated. Use this function to locate the server from a remote location.