30
SuperServer E300-9D User's Manual
Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1.
Power Fail LED
Pin Denitions (JF1)
Pin# Denition
5 3.3V
6 PWR Supply Fail
Overheat (OH)/Fan Fail/PWR Fail LED
Connect an LED cable to pins 7 and 8 of the Front Control Panel to use the Overheat (OH)/
Fan Fail/PWR Fail LED connections. The LED on pin 8 provides warnings of overheat, fan
OH/Fan Fail Indicator Status
State Denition
Off Normal
On Overheat
Flashing Fan Fail/PWR Fail
OH/Fan Fail LED
Pin Denitions (JF1)
Pin# Denition
7 Blue LED
8 OH/Fan Fail/PWR Fail LED
LAN1/LAN2 Activity LED
The LAN LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and the LED
connection for LAN port 2 is on pins 9 and 10. Attach the NIC LED cables here to display
LAN1/LAN2 LED
Pin Denitions (JF1)
Pin# Denition
9 +3.3 Stby
10 LAN2 Activity LED
11 +3.3 Stby
12 LAN1 Activity LED