EasyManua.ls Logo

Supermicro X11DPU - Page 47

Supermicro X11DPU
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
47
Chapter 2: Installation
1. NIC1 LED
2. NIC2 LED
3. Front UID LED
4. OH/Fan Fail LED
5. PWR Fail LED
1
2
3
Power Button
OH/Fan Fail LED
1
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
UID LED
Ground
Ground
19 20
3.3V
X
Ground
NMI
X
Vcc
Vcc
X
X NIC2 Activity LED
NIC1 Activity LED
UID/Overheat (OH)/Fan Fail
Connect an LED cable to UID/OH/Fan Fail connections on pins 7 and 8 of JF1 to provide
front UID LED indication and warnings for chassis overheat/fan failure. Refer to the table
below for pin denitions.
Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table below
for pin denitions.
NIC1/NIC2 (LAN1/LAN2)
The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pin 12 of
JF1, and LAN port 2 is on pin 10. Attach the NIC LED cables here to display network activity.
Refer to the table below for pin denitions.
4
5
LAN1/LAN2 LED
Pin Denitions (JF1)
Pin# Denition
10 NIC2 Activity LED
12 NIC1 Activity LED
Reset Button
Pin Denitions (JF1)
Pin# Denition
7 Front UID LED
8 OH/Fan Fail LED
Power Fail LED
Pin Denitions (JF1)
Pin# Denition
5 3.3V
6 PWR Supply Fail