EasyManua.ls Logo

Sutron X-Link-1 - 19 Appendix A - Specifications

Sutron X-Link-1
192 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sutron Corporation X-Link Operations & Maintenance Manual, Rev 1.63 5/24/2016 pg. 181
19. Appendix A – Specifications
ELECTRICAL
Input Voltage
8-16VDC
10 V minimum for SDI-12 sensor support
Reverse power protected
CURRENT CONSUMPTION @ 12V
Standby (all sensors unpowered)
0.5mA typical
Active
8mA to 20mA typical
Wi-Fi on
18mA typical
GPRSLink and CDMALink modem listening
6.8mA typical
GPRSLink and CDMALink modem transmitting
~100mA typical
MECHANICAL
Dimensions
3.8” x 5.3” x 1.3” (96.5mm x 134.6mm x 33.0mm)
without optional base plate or enclosure
Power Connection
2 position terminal strip
SDI-12 Port
3 position terminal strip
USB Port
Mini B Male (5 pin)
Red Warning LED
Indicates setup or operational error
Green Heartbeat LED
Indicates unit is operating properly
Earth GND
.2” screw terminal
ENVIRONMENTAL
Temperature
-40°C to +60°C
Humidity
0-95% Non-condensing
KEY FEATURES
Clock
Internal real-time clock w/battery backup.
Clock Accuracy
+/- 9.3 s /month(Max) -40 to +60C. (First Year)
+/- 2.4 min /year (Max) -40 to +60C. (First Year)
+/- 4.5 min / 10 years (Max) -40 to +60C. (10 Years)
Log Capacity
240,000 readings, flash memory
Internal Solar Panel
Battery Charger
Designed for 5 to 20W Solar Panels.
Max 30 Watts.

Table of Contents