5.9. Transmissions and Measurements Coinciding
Make sure to have the transmission scheduled a short while after the
measurements are completed. If the measurements happen at the 15-minute
mark, set the transmission time to 16 minutes to ensure the measurements are
completed before the transmission process starts.
If the transmission coincides with the start of measurement collection, chances
are that the most recent measurements will not complete before the
transmission process starts. This will mean that the transmission will contain
missing data!
For example, if the station is set up to sample an SDI-12 sensor every 15 minutes
and transmissions are set up to go once an hour, unless the Tx Time is changed
from 00:00:00, only three readings will appear in the transmission. The Tx Time
must be changed to allow for the measurement to complete. If the SDI-12
reading takes 30 seconds, set the Tx Time to 00:01:00 to ensure ample time for
the measurement to complete before transmissions are started.